PYROLYSIS
EXPERTTHE BUYER’S REFERENCE

Plant types

Plant types and
configurations.

Pyrolysis plants are distinguished less by brand than by two things: the material they are built to swallow, and the operating regime chosen to favour one output over another.

Get help with your project

Axis one

The material decides
the plant.

Feedstock is the dominant design variable. It sets the preparation equipment, the materials of construction, the gas cleaning duty, the character of the liquid and whether the solid residue is a product or a disposal cost. Two plants of identical nominal capacity built for different feedstocks have little in common.

Tires

Consistent by waste standards, but a composite: needs size reduction, usually steel separation, and attention to sulphur species.

Plastics

As much a sorting and cleaning project as a thermal one. Chlorine from PVC constrains equipment life and downstream acceptance.

Biomass

The liquid carries oxygen and water, is acidic and is not indefinitely stable. Plan the commercial model around that, not around diesel.

Read the detail on each feedstock

End-of-life tires

Tires are a relatively consistent feed by waste standards, which is why they are so often the first application considered. They are also a composite: rubber compounds, carbon black, steel reinforcement, textile and vulcanising chemistry including sulphur and zinc. A tire plant therefore needs upstream size reduction and usually steel separation, and it needs to address sulphur species in both the gas and the liquid phase.

The solid output is a carbon-rich char containing the original carbon black plus the inorganic residue. Whether that char can be sold into a demanding application depends on its ash and residual content and on post-processing. Treat any claim that char is directly equivalent to a virgin carbon black grade as a claim to be checked by laboratory analysis of material from the actual plant, assessed against the relevant standard test methods rather than a datasheet assertion.

Mixed and sorted plastics

Polyolefin-rich streams break down into a hydrocarbon liquid that is, in principle, attractive as a feed for further processing. The difficulty is contamination. Chlorine, principally from PVC, generates corrosive species and constrains both equipment life and product acceptability downstream. Food residues, moisture, paper, metals and mineral fillers all report into the process and into the residue.

The practical consequence is that a plastics plant is as much a sorting and cleaning project as a thermal one. If the input specification the process equipment assumes is cleaner than what your supply chain can actually deliver, the plant will not perform as quoted — and the contractual fault line will be the feed specification.

Biomass and wood residues

Biomass pyrolysis is the most studied of these routes and has the most accessible public literature. The liquid product is chemically different from a petroleum-derived oil: it carries substantial oxygen and water, it is acidic, and it is not stable indefinitely in storage. That is the nature of the product rather than a defect in any supplier’s equipment, and a commercial plan has to be built around it.

The solid product — charcoal or biochar, depending on intended use — has its own markets with their own quality expectations. Where soil application is intended, the applicable requirements are set by regulators and voluntary certification schemes in the relevant jurisdiction, and they should be read directly rather than through a vendor’s summary.

Mixed residues and other streams

Sewage sludge, agricultural residues, textile waste, shredder residues and similar materials are all technically pyrolysable. They are also heterogeneous, frequently wet, and often classified as regulated waste. For these streams the determining factors are drying energy, ash and heavy-metal content, and the regulatory status of the residue. A plant producing a residue that requires hazardous-waste disposal has a fundamentally different operating cost structure from one producing a saleable solid.

Three questions that come before the rest

Can you supply a laboratory analysis of your actual material?
A generic figure for the material category is not a substitute. If the analysis does not exist yet, it is the next thing to buy, and it is inexpensive relative to what it protects.
What is the range and the worst case, not the average?
A plant designed for the average composition of a waste stream will meet the extremes in normal operation. Ask what the plant does when it receives them.
Who warrants the feed specification?
In most disputes the central document is the agreed input specification. Know what it says, who warrants that material will meet it, and what happens commercially when a delivery does not.

Axis two

What you are
optimising for.

Within any feedstock, the operating regime shifts the balance between solid, liquid and gas. These distinctions are directional, not numerical: the split for your material is a matter for testing.

Slow / carbonisation

Lower temperature, long solids residence. Chosen when char is the product; capacity comes from size and time.

Fast pyrolysis

High heating rate, short vapour residence, rapid condensation. Chosen when the liquid is the product.

Higher severity or catalytic

Shifts output toward gas, or adds an upgrading step with its own catalyst and utility demands. Often excluded from a quote.

Compare the regimes, and why no percentages appear
RegimeBroad conditions FavoursBuyer implication
Slow pyrolysis / carbonisation Lower temperatures, long residence time for the solids, slow heating The solid carbon fraction Chosen when char is the product. Throughput per unit of plant volume is lower, so capacity comes from size and time rather than intensity.
Fast pyrolysis Higher heating rate, short vapour residence time, rapid condensation The condensed liquid fraction Chosen when liquid is the product. Demands finer, drier feed preparation and places more emphasis on rapid cooling and liquid handling.
Higher-severity / gas-oriented Higher temperatures, conditions that crack vapours further The non-condensable gas fraction Chosen where gas is used for energy or as a chemical intermediate. Shifts the project toward combustion permitting and gas cleaning.
Catalytic or upgrading-coupled Pyrolysis combined with a catalytic or hydroprocessing step A liquid closer to a conventional specification Adds a second process plant with its own catalyst, hydrogen or utility demands. Confirm whether the quotation includes it, because it is frequently excluded.

Why there are no percentages in that table

Product splits quoted without a stated feedstock, analysis and test basis are not information. The same configuration gives materially different results on two materials that share a name. Numbers for a financial model have to be generated from your own material, and the testing basis should be written into the contract.

Configuration

Batch, semi-continuous,
continuous.

The configuration decides your labour model, your availability and whether you can support an offtake contract. The hard engineering sits in feeding material in and taking solids out while keeping air out.

Batch

Simplest and cheapest per unit. Scale comes from multiplying units and the people who run them. Often right for small or intermittent volumes.

Semi-continuous

Can be a sensible middle position, and can also be a more attractive way of describing a batch plant. Ask which steps still require a stop.

Continuous

What an offtake contract generally needs, because a buyer wants consistent material in predictable quantity.

The six questions that separate claim from capability

Material is fed and residue removed without interrupting operation in a continuous plant, which demands feeding and solids-discharge arrangements that maintain oxygen exclusion. That is where most of the real engineering difficulty sits, and it is where these questions point.

All six are answerable. A supplier who cannot answer them about an operating plant is asking you to fund development work. That can still be a reasonable decision — it should simply be a conscious one, priced and structured accordingly.

How is material fed in and solid residue removed while keeping air out?
And what is the demonstrated behaviour of that arrangement over a continuous run, rather than over a demonstration batch?
What is the longest continuous operating period achieved on a comparable feedstock, and what ended it?
The reason the run ended is usually more informative than its length.
Which components are consumable or wear items, at what interval, and are they in the price?
This drives both your spares holding and your availability in year three.
What does the plant do on an unplanned shutdown, and how long is the restart?
Restart time multiplied by realistic trip frequency is an availability figure you can put in a model.
Where does the non-condensable gas go, and is that equipment inside this quotation?
Whether gas is used or flared changes your permit and your energy balance.
What is the turndown, and how does product quality change below design rate?
Plants rarely run at design rate continuously, and the product is what you sell.

Where to check the requirements at source

Offered as further reading. None of these bodies is cited in support of a figure on this site, and none endorses it.

Put the research to work

Your project.
The right questions, answered.

Plant selection, supplier evaluation, feasibility and product markets. Tell us where you are and what you need to establish.

Get project help

Tell us about your project.

Requests are stored privately and reviewed by a person. No response time is promised here, and nothing is published from this form.

Read the privacy notice ↗

Prefer email? Write to [email protected]. The full version of this form is on the project help page.

Submit information

Add to the industry picture.

Submissions go into a private review queue and are checked against their sources before anything is published. Nothing is published automatically, and a listing is not an endorsement.

Read the privacy notice ↗

Prefer email? Write to [email protected]. The full version of this form is on the submit information page.